Vickers Equal (Model Code) | Vickers Assembly # | Remarks |
FCG-H02-16-50B | REL PNDG | |
FCG-H02-50-50B | REL PNDG | |
F3-FCG-H02-50-50B | REL PNDG | |
FCG-H03-100-50B | REL PNDG | |
F3-FCG-H03-100-50B | REL PNDG | |
DG4V322AVMUH760 | 871847 | |
DG17V32N60EN422 | 02-148697 | |
DG17V32C60 | 02-127343 | |
DG17V38C60 | 02-140909 | |
DG17V36C60 | 02-135316 | |
DG17V36C60 | 02-135316 | DG17V-3 IS STANDARD VITON |
DG17V36N60 | 02-135673 | |
DG4V322AVMUH760 | 871847 | |
DG4V30AVMUH760 | REL PNDG | |
DG4V32AZVMUH760 | REL PNDG | |
DG4V32AVMUH760 | 859188 | |
DG4V32AVMUH760 | 859188 | |
DG4V32AVMUH760P12 | REL PNDG | |
DG4V32AVMUH760 | 859188 | |
DG4V32AVMUB660 | 870890 | |
DG4V32AVMUD660 | REL PNDG | |
DG4V32NVMUH760 | 859164 | |
DG4V32NVMUH760 | 859164 | |
DG4V32NVMUH760P12 | REL PNDG | |
DG4V32NVMUH760 | 859164 | |
DG4V32NVMUDJ760 | 859164 | |
DG4V32NVMUB660 | 02-108674 | |
DG4V32NVMUD660 | 02-145712 | |
DG4V32CVMUH760 | 859213 | |
DG4V32CVMFTWLH760 | REL PNDG | |
DG4V32CVMUB660 | 870662 | |
DG4V32CVMUD660 | REL PNDG | |
DG4V32C209VMUHH760 | REL PNDG | |
DG4V30BLVMUH760 | REL PNDG | |
DG4V30BMUH760 | ||
DG4V36CVMUH760 | 859183 | |
DG4V36CVMUH760 | 859183 | |
DG4V36CVMUH760P12 | REL PNDG | |
DG4V36CVMUH760 | 859183 | |
DG4V36CVMUB660 | 859486 | |
DG4V36CVMUD660 | 870406 | |
DG4V36CVMUD660P10 | REL PNDG | |
DG4V36BLVMUH760 | 870875 | |
DG4V36BLVMUD660 | REL PNDG | |
DG4V37CVMUH760 | 870404 | |
DG4V32ALVMUH760 | 859211 | |
DG4V32ALVMUH760P12 | REL PNDG | |
DG4V32ALVMUH760 | 859211 | |
DG4V32ALVMUB660 | 859481 | |
DG4V32ALVMUD660 | 870953 | |
DG3VP-3-103A-V-M-U-P-10 | 507606 | |
DG3VP-3-103A-V-M-U-H-10 | 638538 | |
DG3VP-3-103A-V-M-U-P-10 | 507606 | |
DG3VP-3-102A-V-M-U-H-10 | 638542 | |
DG3VP-3-102A-V-M-U-H-10 | 638542 | |
DG4V522AJVMUH620 | REL PNDG | |
DG4V522ALJVMUH620 | REL PNDG | |
DG4V50AVMUEK620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W110 IS DUAL FREQUENCY |
DG4V52AJVMUH620 | REL PNDG | |
DG4V52NJVMUH620 | REL PNDG | |
DG4V52NJVMUH620 | REL PNDG | |
DG4V52NJVMUH620 | REL PNDG | |
DG4V52AJVMUH620J12 | REL PNDG | |
DG4V52CJVMUH620 | REL PNDG | |
DG4V52CJVMUEK620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W110 IS DUAL FREQUENCY |
DG4V52CJVMUEH620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W230 IS DUAL FREQUENCY |
DG4V56CJVMUH620 | REL PNDG | |
DG4V56CJVMUH620 | REL PNDG | |
DG4V56CJVMUH620 | REL PNDG | |
DG4V56CJVMUH620 | REL PNDG | |
DG4V56CJVMUEK620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W110 IS DUAL FREQUENCY |
DG4V56CJVMUEK620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W110 IS DUAL FREQUENCY |
DG4V56CJVMUEH620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W230 IS DUAL FREQUENCY |
DG4V531CJVMUH620 | REL PNDG | |
DG4V52ALJVMUH620 | REL PNDG | |
DG4V52ALJVMUEK620 | REL PNDG | DG4V5 VALVES HAVE SINGLE FREQUENCY COILS, RR W110 IS DUAL FREQUENCY |
DG4V52ALJVMUH620J12 | REL PNDG | |
DG5V56CTVMUH710 | REL PNDG | |
DG17V4012N10 | 02-356396 | |
DG17V4-01-6C-10 | 02-356393 | |
DG17V4-01-6N-10 | 02-356397 | |
DG4V5-6C-J-M-U-H6-20 | 616780 | |
DG5V72AL4TVMUH730P10 | REL PNDG | |
DG5V72AL4TVMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V72AL2TVMUH730 | REL PNDG | |
DG5V72CTVMUH730 | REL PNDG | |
DG5V72N4VMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
F3DG5V72N4VMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V72NTVMUH730 | 02-146691 | |
DG5V72N4TVMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V72N2TVMUH730 | REL PNDG | |
DG5V72N6TVMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V72N4EVMUH730P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V72N6TVMUB630P10, SEE COMMENTS | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76CTVMUH730 | 02-350591 | |
DG5V76CTVMUH730 | 02-350591 | |
DG5V76C4TVMUH730P10 | REL PNDG | |
DG5V76C4TVMUH730P10 | REL PNDG | |
DG5V76C4TVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
F3DG5V76C4TVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
F3DG5V76CTVMUH730 | 02-350591 | |
DG5V76C2TVMUH730 | 02-358669 | |
DG5V76C6TVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76C6TVMUH730 | REL PNDG | |
DG5V76C6TVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76C4EVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76C2PPDETVMUH730 | REL PNDG | |
DG5V76C4HTVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76C4TVMUB630P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V76C4TVMUC630P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
F3DG5V72AL4TVMUH730P10 | REL PNDG | RR D3 = PRESSURE REDUCING VALVE, VICKERS DOES NOT OFFER THE OPTION WITH THE D07 ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION DG5V-7 WITH IT |
DG5V8HR2AEVMUHP1010 | REL PNDG | |
DG5V8H2A2EVMUH10 | REL PNDG | |
DG5V8HR2AEVMUBP1010 | REL PNDG | |
DG5V8H2BLEVMUH10 | REL PNDG | |
DG5V8HR2BLEVMUHP1010 | REL PNDG | |
DG5V8HR2BLEVMUBP1010 | REL PNDG | |
DG5V8SR2NTVMUHP1010 | REL PNDG | |
DG5V8H6CVMUH10 | REL PNDG | |
DG5V8SR6CTVMUHP1010 | REL PNDG | |
DG5V8HR33C2EVMUHP1010 | REL PNDG | |
DG5V72A4TVMUH730P10 | REL PNDG | NO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING MODULE |
DG5V72A4TVMUH730P10 | REL PNDG | NO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING MODULE |
DG5V72N6TVMUH730P10 | REL PNDG | NO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING MODULE |
DG5V8HR2ATVMUHP1010 | REL PNDG | RR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS |
DG5V8HR2AEVMUDP1010 | REL PNDG | RR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS |
DG5V8HR2A2EVMUDP1010 | REL PNDG | RR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS |
DG5V8HR2BLEVMUDP1010 | REL PNDG | |
F3DG5V8HR2NTVMUHP1010 | REL PNDG | |
DG5V8H6CTVMUH10 | REL PNDG | |
DG5V8H6CTVMUH10 | REL PNDG | |
DG5V8HR6CTVMUHP1010 | REL PNDG | |
DG5V8HR6CTVMUHP1010 | REL PNDG | |
F3DG5V8HR6CTVMUHP1010 | REL PNDG | |
DG5V8H6C2TVMUH10 | REL PNDG | |
DG5V8HR6C2TVMUHP1010 | REL PNDG | |
DG5V8HR6CTVMUHP1010 | REL PNDG | |
DG5V8HR6C2EVMUHP1010 | REL PNDG | |
DG5V8HR6CTVMUBP1010 | REL PNDG | |
DG5V8HR6CTVMUDP1010 | REL PNDG | |
DG5V10S6CTVMUH10 | 02-390437 | |
KDG4V333C07NZVMUH760 | REL PNDG | MUST USE VICKERS ELECTRONICS |
KDG4V333C07N03FVMUH760 | REL PNDG | MUST USE VICKERS ELECTRONICS |
KDG4V333C20N10ZVMUH760 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 30/15 L/MIN, VICKERS IS 20/10 L/MIN |
KDG4V333C20N10VMUH760 | 02-411097 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 30/15 L/MIN, VICKERS IS 20/10 L/MIN |
KDG4V333C20NZVMUH760 | 02-156215 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 30 L/MIN, VICKERS IS 20 L/MIN |
KBDG4V333C20N10ZVM2PE7H710 | REL PNDG | RR SPOOL RATED TO 30/15 L/MIN, VICKERS IS 20/10 L/MIN |
KBDG4V333C13NZVM2PE7H710 | REL PNDG | RR SPOOL RATED TO 15 L/MIN, VICKERS IS 13 L/MIN, IF NECESSARY CAN GO WITH 33C20N SPOOL AND HAVE 20 L/MIN |
KDG4V533C50N25ZVMUH730 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 60/30 L/MIN VICKERS IS 50/25 L/MIN |
KDG4V533C50N25VMUH730 | 02-411098 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 60/30 L/MIN VICKERS IS 50/25 L/MIN |
KDG4V533C50NZVMUH730 | 869901 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 60 L/MIN VICKERS IS 50 L/MIN |
KFDG4V32C07NZVMU1H720 | 565373 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 8 L/MIN, VICKERS IS RATED 7 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V32C20NZVMU1H720 | 565377 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16 L/MIN, VICKERS IS RATED 20 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20N10ZVMU1H720 | 02-358167 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16/8 L/MIN, VICKERS IS RATED 20/10 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20N10ZVMU1H720 | 02-358167 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16/8 L/MIN, VICKERS IS RATED 20/10 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20N10ZVMU1H720 | 02-358167 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16/8 L/MIN, VICKERS IS RATED 20/10 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20N10ZVMU1H720 | 02-358167 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16/8 L/MIN, VICKERS IS RATED 20/10 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20NZVMU1H720 | 565384 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 16 L/MIN, VICKERS IS RATED 20 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V333C20NZVMU1H720 | 565384 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 32 L/MIN, VICKERS IS RATED 20 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V533C50N25ZVMUH720 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL 25/13 L/MIN SPOOL, VICKERS IS 50/25 L/MIN. CAN REF ASSY #02-352069, KFDG4V533C50N25ZVMU1H720 |
KFDG4V533C50N25ZVMUH720 | REL PNDG | MUST USE VICKERS ELECTRONICS CAN REF ASSY #02-352069, KFDG4V533C50N25ZVMU1H720 |
KFDG4V533C50N25ZVMUH720 | REL PNDG | MUST USE VICKERS ELECTRONICS CAN REF ASSY #02-352069, KFDG4V533C50N25ZVMU1H720 |
KFDG4V533C50N25ZVMUH720 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS 50/25 L/MIN CAN REF ASSY #02-352069, KFDG4V533C50N25ZVMU1H720 |
KFDG4V533C50N25ZVMU1H720 | 02-352069 | MUST USE VICKERS ELECTRONICS RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS 50/25 L/MIN ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KFDG4V533C50NZVMU1H720 | 565321 | MUST USE VICKERS ELECTRONICS ASSY GIVEN COMES WITH THE DIN CONNECTORS ASSEMBLED ON THE VALVE |
KBFDG4V35C20NZM1PE7H711 + EHA-CON-201-A-20 |
REL PNDG + 5996156-001 |
RR SPOOL IS RATED 16 L/MIN, VICKERS IS 20 L/MIN THE EHA-CON-201-A-20 IS FOR THE F1 CODE, ±10mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V35C20NZVPE7H710 + EHA-CON-201-A-20 |
REL PNDG + 02-104839 |
RR SPOOL IS RATED 16 L/MIN, VICKERS IS 20 L/MIN THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V333C07NZVPE7H710 + EHA-CON-201-A-20 |
REL PNDG + 02-104839 |
RR SPOOL IS RATED 8 L/MIN, VICKERS IS 7 L/MIN THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V333C20N10ZVPE7H710 + EHA-CON-201-A-20 |
REL PNDG + 02-104839 |
RR SPOOL IS RATED 8/4 L/MIN, VICKERS IS 20/10 L/MIN, ONLY ASSYEMTRICAL SPOOL WE HAVE IN THE KBFDG4V3. THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V59C50NZVPE7H710 | REL PNDG | |
KBFDG4V533C50N25ZVPE7H710 + EHA-CON-201-A-20 |
02-359630 + 02-104839 |
RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS 50/25 L/MIN. THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V533C50NZVPE7H710 + EHA-CON-201-A-20 |
02-352308 + 02-104839 |
THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG4V533C50NZVPE7H710 + EHA-CON-201-A-20 |
02-352308 + 02-104839 |
THE EHA-CON-201-A-20 IS FOR THE F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC |
KBFDG5V833C375N250XTM1PE7H410 | REL PNDG | RR SPOOL IS 220/110 L/MIN, VICKERS IS 375/250 L/MIN |
KBFDG5V833C375N250XTM2PE7H410 | REL PNDG | RR SPOOL IS 220/110 L/MIN, VICKERS IS 375/250 L/MIN |
KBFDG5V833C375N250XTM2PE7H410 | REL PNDG | RR SPOOL IS 350/175 L/MIN, VICKERS IS 375/250 L/MIN |
KBSDG4V596L80PE7H710 + EHACON201A20 |
02-350062 + 02-104839 |
RR SPOOL IS RATED 100 L/MIN, VICKERS IS 80 L/MIN THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1 ON THE RR, VICKERS IS 0-10VDC |
KBSDG4V396L40PE7H710 + EHACON201A20 |
02-333476 + 02-104839 |
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1 ON THE RR, VICKERS IS 0-10VDC |
INCOMPLETE CODE, MISSING THE COMPLETE SPOOL CODE |
||
KSDG4V396L40MU1H711 | 02-310817 | MUST USE VICKERS ELECTRONICS VALVE GIVEN COMES WITH DIN CONNECTOR PLUGS ASSEMBLED ON THE VALVE |
KBFDG4V59C50NZVPE7H710 | REL PNDG | |
KBFDG4V35C20NZVPE7H710 | REL PNDG | RR SPOOL RATED TO 4 L/MIN, VICKERS 20 L/MIN LOWEST FLOW AVAILABLE IN ZERO LAP SPOOL |
KBFDG4V35C20NZVPE7H710 | REL PNDG | RR SPOOL RATED TO 10 L/MIN, VICKERS 20 L/MIN LOWEST FLOW AVAILABLE IN ZERO LAP SPOOL |
KBSDG4V396L05PE7H710 | 02-333472 | RR SPOOL IS RATED 4 L/MIN, VICKERS IS 5 L/MIN |
KBHDG5V52C100NXTPE7H410 + EHACON201A20 |
02-359450 + 02-104839 |
RR SPOOL IS RATED 50 L/MIN, VICKERS IS 100 L/MIN THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1 ON THE RR, VICKERS IS 0-10VDC |
KBHDG5V55C85NEXPE7H410 | 5996495-001 | RR SPOOL RATED 100 L/MIN, VICKERS 85 L/MIN |
KBHDG5V75C200NEXPE7H410 | 02-350960 | RR SPOOL RATED 125 L/MIN, VICKERS 200 L/MIN |
KBHDG5V75C200NXTPE7H410 + EHACON201A20 |
REL PNDG + 02-104839 |
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1 ON THE RR, VICKERS IS 0-10VDC |
KBHDG5V733C160NXTPE7H410 + EHACON201A20 |
02-352351 + 02-104839 |
RR SPOOL IS RATED 125 L/MIN, VICKERS IS 160 L/MIN THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1 ON THE RR, VICKERS IS 0-10VDC |
KDG5V52C90NEXVMUH110 | 02-359445 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 50 L/MIN, VICKERS 90 L/MIN |
KDG5V52C90NXTVMUH110 | 02-333827 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 85 L/MIN, VICKERS 90 L/MIN |
KDG5V52C90NTVMUH110 | 02-352717 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 85 L/MIN, VICKERS 90 L/MIN |
KDG5V533C80NXTVMUH110 | 02-323534 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 50 L/MIN, VICKERS 80 L/MIN |
KDG5V533C80NXTVMUH110 | 02-323534 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 50 L/MIN, VICKERS 80 L/MIN |
KDG5V533C60N40XTVMUH110 | 02-411790 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 50/25 L/MIN, VICKERS 60/40 L/MIN |
KDG5V533C60N40XVMUH110 | 02-358195 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN |
KDG5V533C60N40XTVMUH110 | 02-411790 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN |
KDG5V533C60N40XTVMUH110 | 02-411790 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN |
KDG5V72C180N100XTVMUH110 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150/75 L/MIN VICKERS 180/100 L/MIN |
KDG5V733C170NXVMUH110 | 02-318387 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150 L/MIN VICKERS 170 L/MIN |
KDG5V733C170NXTVMUH110 | 02-358953 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150 L/MIN VICKERS 170 L/MIN |
KDG5V733C130N65XTVMUH110 | 02-411791 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 100/50 L/MIN, VICKERS 130/65 L/MIN |
KDG5V733C130N65XTVMUH110 | 02-411791 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN |
KDG5V733C130N65EVMUH110 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN |
KDG5V733C130N65EXTVMUH110 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN |
KDG5V833C270NXTVMUH110 | 02-352401 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 220 L/MIN VICKERS 270 L/MIN |
KDG5V833C270NXTVMUH110 | 02-352401 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 220 L/MIN VICKERS 270 L/MIN |
KDG5V833C270NXTVMUH110 | 02-352401 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 325 L/MIN VICKERS 270 L/MIN |
KDG5V833C250N170XTVMUH110 | 02-411099 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN |
KDG5V833C250N170XTVMUH110 | 02-411099 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN |
KDG5V833C250N170XVMUH110 | 02-350373 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN |
KDG5V833C250N170XTVMUH110 | 02-411099 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN |
KDG5V833C250N170XTVMUH110 | 02-411099 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN |
KDG5V8133C250N170EXVMUH110 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN |
KDG5V102C550NXTVMUH111 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN |
KDG5V1033C550NXTVMUH111 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN |
KDG5V1033C550NXTVMUH111 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN |
KDG5V1033C550NEXVMUH111 | 02-396736 | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN |
KDG5V1033C550N310XTVMUH111 | REL PNDG | MUST USE VICKERS ELECTRONICS RR SPOOL RATED TO 520/260 L/MIN, VICKERS IS 550/310 L/MIN |
KBDG5V52C70N45XTM1PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 85/43 L/MIN, VICKERS 70/45 L/MIN |
KBDG5V533C80NXTM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 50 L/MIN, VICKERS IS 80 L/MIN |
KBDG5V533C60N40XTM1PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN |
KBDG5V533C60N40XTM2PE7H110 | 02-353663 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN |
KBDG5V533C60N40XTM2PE7H110 | 02-353663 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN |
KBDG5V533C60N40XTM2PE7H110 | 02-353663 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 85/43 L/MIN, VICKERS IS 60/40 L/MIN |
KBDG5V72C180N100XTM1PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 150/75 L/MIN, VICKERS IS 180/100 L/MIN |
KBDG5V733C130N65EM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 100/50 L/MIN, VICKERS IS 130/65 L/MIN |
KBDG5V733C130N65XTM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 175/88 L/MIN, VICKERS IS 130/65 L/MIN |
KBDG5V733C130N65EXTM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 175/88 L/MIN, VICKERS IS 130/65 L/MIN |
KBDG5V82C330N200XTM1PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN |
KBDG5V833C330NXTM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 325 L/MIN, VICKERS IS 330 L/MIN |
KBDG5V833C330N200XTM2PE7H110 | 02-411348 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 220/110 L/MIN, VICKERS IS 330/200 L/MIN |
KBDG5V833C330N200XTM2PE7H110 | 02-411348 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 220/110 L/MIN, VICKERS IS 330/200 L/MIN |
KBDG5V833C330N200XTM2PE7H110 | 02-411348 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN |
KBDG5V833C330N200XTM2PE7H110 | 02-411348 | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN |
KBDG5V102C550N310EXM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 520/260 L/MIN, VICKERS IS 550/310 L/MIN |
KBDG5V1033C550N310XTM2PE7H110 | REL PNDG | EUROPEAN SOLENOID IDENTIFICATION IS NOT AN OPTION ON THIS SERIES RR SPOOL RATED 360/180 L/MIN, VICKERS IS 550/310 L/MIN |
SM4-20(5)19-300/30-50-S46, + SM4A-5-20-50 |
REL PNDG + 927783 |
RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm S46 = REXROTH WIRING, NO NEED TO RE-WIRE CONNECTOR |
SM4-20(12)45-300/30-50-S10, + SM4A-5-20-50 |
REL PNDG + 927783 |
S10 IS FOR 5TH PORT ACTIVATED, EXT PILOT WHICH EQUALS RR “T”, WILL HAVE TO RE-WIRE CONNECTOR, DO NOT HAVE A SPECIAL FOR S10+ S46 COMBINATION, MAY CONSIDER MPS TO CREATE ONE RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm |
SM4-10(2.5)9-300/30-10-S46 + SM4A-3-10-10 |
REL PNDG + 686617 |
RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm S46 = REXROTH WIRING, NO NEED TO RE-WIRE CONNECTOR |
DARV-H-6-K-10/315 | REL PNDG | |
DARV-W-10-G-10/100 | REL PNDG | |
F3-DARV-W-10-G-10/100 | REL PNDG | |
DARV-W-10-G-10/200 | REL PNDG | |
DARV-W-10-G-10/315 | REL PNDG | |
DARV-W-10-K-10/200 | REL PNDG | |
DARV-W-10-K-10/25 | REL PNDG | |
DARV-W-10-K-10/315 | REL PNDG | |
DARV-W-10-P-10/200 | REL PNDG | |
F3-DARV-W-10-P-10/200 | REL PNDG | |
DARV-W-10-P-10/315 | REL PNDG | |
NO VICKERS | N/A | Rexroth Safety valve with design testing to DGRL 97/23/EG |
NO VICKERS | N/A | Rexroth Safety valve with design testing to DGRL 97/23/EG |
DARV-W-20-G-10/200 | REL PNDG | |
DARV-W-20-G-10/315 | REL PNDG | |
DARV-W-20-K-10/315 | REL PNDG | |
DARV-W-20-P-10/100 | REL PNDG | |
DARV-W-20-P-10/200 | REL PNDG | |
F3-DARV-W-20-P-10/200 | REL PNDG | |
NO VICKERS | N/A | Rexroth Safety valve with design testing to DGRL 97/23/EG |
NO VICKERS | N/A | Rexroth Safety valve with design testing to DGRL 97/23/EG |
DARV-W-20-P-10/315 | REL PNDG | |
F3-DARV-W-20-P-10/315 | REL PNDG | |
DARV-W-20-P-10/400 | REL PNDG | |
DARV-W-30-G-10/25 | REL PNDG | |
DARV-W-30-K-10/200 | REL PNDG | |
DARV-W-30-K-10/315 | REL PNDG | |
DARV-W-30-P-10/200 | REL PNDG | |
F3-DARV-W-30-P-10/200 | REL PNDG | |
DARV-W-30-P-10/315 | REL PNDG | |
DARV-W-6-G-10/200 | REL PNDG | |
DARV-W-6-K-10/200 | REL PNDG | |
DARV-W-6-K-10/315 | REL PNDG | |
DARV-W-6-K-10/315-230 | REL PNDG | |
DARV-W-6-P-10/100 | REL PNDG | |
DARV-W-6-P-10/200 | REL PNDG | |
DARV-W-6-P-10/315 | REL PNDG | |
DARV-W-6-P-10/315-210 | REL PNDG | |
F3-DARV-W-6-P-10/315 | REL PNDG | |
DARV-W-6-P-10/400 | REL PNDG | |
CG2V-6-FW-10 | 615025 | |
CG2V-6-FW-1-10 | 507130 | |
CG2V-6-GW-10 | 615026 | |
CG2V-6-BW-10 | 615023 | |
CG2V-8-CW-10 | 615028 | |
CG2V-8-CW-10 | 615028 | |
CG2V-8-FW-10 | 615029 | |
CG2V-8-FW-10 | 615029 | |
F3-CG2V-8-FW-10 | 992376 | |
CG2V-8-FW-1-10 | 992267 | |
CG2V-8-FW-10 | 615029 | |
CG2V-8-GW-10 | 615030 | |
CG2V-8-GW-10 | 615030 | |
CG2V-8-GW-10 | 615030 | |
CG2V-8-GW-10 | 615030 | |
F3-CG2V-8-GW-10 | 991901 | |
CG2V-10GW-B-10 | 02-412582 | |
CG2V-10BW-B-U-10 | 02-412579 | |
CG2V-10FW-B-10 | 02-412580 | |
CG2V-10GW-B-10 | REL PNDG | “E” not recognized in Rexroth model code |
CG2V-10GW-B-10 | 02-412582 | |
CG5V-6-GW-D-V-M-U-H7-11 | 859544 | |
CG5V-6-GW-D-V-M-U-H7-11, W/O rexroth SPECIAL OPT | NO INFORMATION ON SPECIAL OPT | |
CG5V-6-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT | NO INFORMATION ON SPECIAL OPT | |
CG5V-6-GW-D-V-M-U-H7-11,W/O Rexroth SPECIAL OPT | NO INFORMATION ON SPECIAL OPT | |
“A” NC TYPE NOT OFFERED IN VICKERS, ONLY THE “B” NO | NO VICKERS | |
CG5V-8-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT | NO INFORMATION ON SPECIAL OPT | |
CG5V-8-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT | NO INFORMATION ON SPECIAL OPT | |
CG5V-8-GW-D-V-M-U-HH5-20-P12-EN6 | REL PNDG OR MPS |
MAY TAKE AN MPS BECAUSE OF THE P12, 1,2MM ORIFICE IN THE PILOT VALVE, EN6 IS FOR SOFTSHIFT PILOT TO EQUAL RR “S” OPTION |
CG5V-10GW-B-1-M-U-H7-10 | 02-412650 | |
CG5V-10GW-B-2-M-U-H7-10 | 02-412651 | “SO160” not recognized (preset at 160 bar?) |
CG5V-10HW-B-2-M-U-H7-10 | 02-412652 | “SO160” not recognized (preset at 160 bar?) |
CG5V-10BW-B-U-2-M-U-H7-10 | 02-412649 | |
KCG-6-W250-1-Z-M-U-H1-10 + EEA-PAM-513-A-32 |
02-155961 + 02-326016 |
|
NO DIRECT VICKERS | THE “M” IS FOR MAX PRESSURE PROTECTION, KCG SERIES DOES NOT OFFER THAT, OLD CGE SERIES DID BUT IT IS AN OUTDATED PRODUCT BEING PHASED OUT, AND IT DOES NOT HAVE THE PRESSURE RATING OF THE RR |
|
KCG-3-160-D-Z-M-U-H1-10 + EEA-PAM-513-A-32 |
02-145957 + 02-326016 |
|
KCG-3-250-D-Z-M-U-H1-10 + EEA-PAM-513-A-32 |
02-145958 + 02-326016 |
|
KCG-3-250-D-Z-M-U-H1-10 + EEA-PAM-513-A-32 |
02-145958 + 02-326016 |
|
KBCG-3-250-Z-M2-2-A-PE7-H1-10 | 02-352751 | |
NO DIRECT VICKERS | THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT OPERATED VERSION |
|
NO DIRECT VICKERS | THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT OPERATED VERSION |
|
NO DIRECT VICKERS | THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT OPERATED VERSION |
|
NO DIRECT VICKERS | THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT OPERATED VERSION |
|
NO DIRECT VICKERS | THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT OPERATED VERSION |
|
XCG2V6CW10 | 615003 | |
XCG2V6FW10 | 615004 | |
XG2V6FW10 | 709411 | |
XCG2V6GW10 | 615005 | |
XG2V6GW10 | 709412 | |
XCG2V6BW10 | 615002 | |
XT-H10-3-30 | 02-101800 | ONLY POSSIBLE VICKERS IN THIS MOUNTING TYPE, VICKERS RATED 210 BAR, RR 315 BAR, RR IS 1″ VICKERS IS 1 1/4″ |
F3XCG22V8CW10 | 991904 | |
XCG2V8FW10 | 615008 | |
XG2V8FW10 | 709416 | |
F3XCG2V8FW10 | 507603 | |
XCG2V8GW10 | 615009 | |
XCG2V8BW10 | 615006 | |
XCG2V-10CW-B-10 | 02-412641 | |
F3-XCG2V-10CW-B-10 | 02-412642 | |
XCG2V-10FW-B-10 | 02-412643 | |
XG2V-10FW-B-10 | 02-412644 | |
F3-XCG2V-10FW-B-10 | 02-412645 | |
XCG2V-10BW-B-10 | 02-412647 | |
F3-XCG2V-10BW-B-10 | 02-412648 | |
KBXCG-6-W250-Z-M1-3-A-PE7-H1-10 | 02-352965 | |
KBXG-8-W250-Z-M1-3-A-PE7-H1-10 | 02-353115 | |
CVU16-EFP1-B29-19-31 + EEA-PAM-571-A-32 |
515866 + 02-326007 |
MUST USE VICKERS ELECTRONICS, EEA-PAM-571-A-32 |
CVU-32-EFP1-B29-70-31 + EEA-PAM-571-A-32 |
02-156730 + 02-326007 |
RR RATED TO 450 L/MIN, VICKERS IS 700 L/MIN MUST USE VICKERS ELECTRONICS, EEA-PAM-571-A-32 |
NO DIRECT VICKERS | VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3 BOURDON PRESSURE TUBE STYLE |
|
NO DIRECT VICKERS | VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3 BOURDON PRESSURE TUBE STYLE |
|
NO DIRECT VICKERS | VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3 BOURDON PRESSURE TUBE STYLE |
|
ST307-350-B | 02-139179 | |
SG307-F-350 + DGMP-3-*-B-10 | * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTH’S IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE. RR WOULD WORK FOR ANY PORT BASED ON ASSEMBLY POSITION |
|
CVI16R16L40 | 02-156327 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR VICKERS CLOSEST IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI25R16L40 | 02-156356 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR VICKERS CLOSEST IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFO ON THE -004 W/O IT CVI25R16M40 |
02-156364 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFO ON THE -004 W/O IT CVI25D202H10 |
580069 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI25D10H40 | 02-156365 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 3,1 BAR VICKERS RATE GIVES THE VICKERS THE BEST PERFORMANCE WHEN USED WITH THE RELIEF COVER NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32R16L40 | 02-156388 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32R16L40 | 02-156388 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
F3CVI32R16L40 | 02-359439 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32R16L40 | 02-359439 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32D202L10 | 815243 | RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST IS 0,5 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFO ON THE -004 W/O IT CVI32R16M40 |
02-156396 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32D105M40 | 02-156391 | RR HAS A RATIO OF 1:1.07 (14.3:1), VICKERS IS 1:1.05. ALSO RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 1,65 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32D105H40 | 02-156398 | RR HAS A RATIO OF 1:1.07 (14.3:1), VICKERS IS 1:1.05. ALSO RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 3,3 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI32D10H40 | 02-156397 | RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 3,1 BAR THIS IS FOR THE BEST PERFORMANCE WHEN USED WITH VICKERS PRESSURE CONTROL COVERS NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40R16L40 | 02-323089 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40R16L40 | 02-323089 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR VICKERS IS 0,6 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40D202L10 | 579932 | NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40R16M40 | 02-323090 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40R16M40 | 02-323090 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40R16M40 | 02-323090 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 4,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFORMATION ON -004 W/O IT CVI40R16M40 |
02-323090 | RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 4,0 BAR VICKERS CLOSEST IS 3,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40D202H10 | 579934 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
F3CVI40D202H10 | 633048 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40C10FC40 | 02-323120 | RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 2,35 BAR FOR THE BEST PERFORMANCE WITH VICKERS PRESSURE RELIEF COVERS NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFORMATION ON -104 W/O IT CVI40D10C40 |
02-323119 | RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 2,35 BAR FOR THE BEST PERFORMANCE WITH VICKERS PRESSURE RELIEF COVERS NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI40X240 | 02-323038 | ONLY VICKERS INSERT FOR PRESSURE REDUCING FUNCTION NOT ENOUGH INFORMATON ON THE RR TO COMPLETELY VALIDATE CROSS NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI50R2L10 | 455998 | RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST IS 0,5 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI50D202L10 | 589114 | RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST IS 0,5 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFORMATION ON -104 W/O IT CVI50D202M10 |
589115 | RR CRACKING PRESSURE IS 2,0 BAR, VICKERS CLOSEST IS 2,5 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
DO NOT HAVE INFORMATION ON -104 W/O IT CVI50R2H10 |
455997 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI50D202H10 | 589116 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI63R2L10 | 456013 | RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST IS 0,5 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVI63D202H10 | 589139 | RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST IS 5,0 BAR NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO INFORMATION LCT SERIES | ||
NO INFORMATION LCT SERIES | ||
NO INFORMATIONON L-DB SERIES | ||
NO INFORMATIONON L-DB SERIES | ||
CVCS-16-W13-B29-10-A12-P12 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-16-D3-B29-10 | 455820 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-16-D3-B29-10-AP108 | 515316 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-25-N-B29-10 | 02-156945 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-25-N-B29-10-X15 | REL PNDG | VICKERS DOES NOT OFFER SEPARATE VERSION FOR THE RR “F” OPTION, REMOTE CONTROL PORT, ON THE VICKERS THE PILOT PORT CAN BE ACCESSED EXTERNALLY FOR REMOTE CONTROL NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO INFORMATION ON THE 006 W/O IT CVCS-25-X3-B29-W350-11 |
02-318459 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-25-A-B29-W-10 | 02-156453 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO INFORMATION | ||
CVCS-32-N-B29-10 | 02-330771 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-N-B29-10 | 02-330771 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-N-S2-10 | 730414 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO VICKERS | PRESSURE CONTROL COVER WITH 420 BAR PRESSURE ADJ VICKERS MAX IS 350 BAR NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
|
CVCS-32-W13-B29-10 | 02-154714 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-W13-B29-10-A12-P12 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-A-B29-W-10 | 02-344576 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-A-B29-W-10 | 02-344576 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
F3-CVCS-32-A-B29-W-10 | 02-344577 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10 | 02-154718 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10-AP110-P10-T10 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10-AP112 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10-AP112-P15 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10-P15 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-32-D3-B29-10-AP100-AP212 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-N-B29-10 | 02-333629 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-N-B29-10 | 02-333629 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-N-B29-10-X25 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-C-B29-W350-11 | 02-342408 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-C-B29-W125-11 | 02-319895 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-C-B29-W350-11 | 02-342408 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-W13-B29-10-A12 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-W13-B29-10-A20 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-W13-B29-10 | REL PNDG | VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE RR, USE STANDARD OR NO CROSS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-A-B29-W-10-X12 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-A-B29-W-10-X12 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO VICKERS | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
|
CVCS-40-D3-B29-10 | 637287 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-D3-B29-10 | 637287 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-D3-B29-10-AP115 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-40-D3-B29-10-AP115-P15 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
F3-CVCS-40-D3-B29-10-AP115 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-N-B29-10 | 02-342721 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-N-B29-10 | 02-342721 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-N-B29-10 | 02-342721 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-N-B29-10-X18 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-N-B29-10-X30 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-W13-S2-10-S32 | 02-330798 | THE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-W13-S2-10-S32-A15 | REL PNDG | THE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-W13-S2-10-S32 | 02-330798 | THE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE RR, USE STANDARD OR NO CROSS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
NO INFORMATION | ||
NO VICKERS | ||
CVCS-50-D3-S2-10-S32-AP115 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-D3-S2-10-S32-AP115-P15 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-D3-S2-10-S32-AP130 | REL PNDG | VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE RR, USE STANDARD OR NO CROSS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-D3-S2-10-S32 | REL PNDG | VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE RR, USE STANDARD OR NO CROSS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVCS-50-D3-S2-10-S32 | REL PNDG | VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE RR, USE STANDARD OR NO CROSS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVC-63-N-B29-10 | 456003 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVC-63-N-B29-10-X18 | REL PNDG | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVC-63-N-B29-10-X35 | 02-411792 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
CVC-63-A-B29-W-10 | 456004 | NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS CANNOT MIX AND MATCH WITH RR COMPONENTS |
DT8P1-06-15-11 | 222319 | RR HAS 1/2 BSPP THREADS, VICKERS HAS 3/4 NPTF, DO NOT OFFER BSPP FOR THIS SERIES OR IN THE 1/2 SIZE |
DT8P1-06-15-11 | 222319 | RR HAS 3/4 BSPP THREADS, VICKERS HAS 3/4 NPTF, DO NOT OFFER BSPP FOR THIS SERIES |
DT8P1-10-0-11-S261 | 417856 | S261 VICKERS IS FOR NO SPRING WHICH IS EQUAL TO RR “0”,IT IS FOR LIGHT DUTY USE ONLY |
DT8P1-10-5-11 | 125667 | BOSCH HAS BSPP THREADS, VICKERS HAS NPTF, DO NOT OFFER BSPP |
DT8P1-03-5-10 | BOSCH HAS BSPP THREADS, VICKERS HAS NPTF, DO NOT OFFER BSPP |
|
PCGV-6-A-D-1-10 | 615045 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
F3-PCGV-6-A-D-1-10 | 507359 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
PCGV-6-F-D-1-10 | 615047 | |
PCGV-6-A-1-10 | 615042 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
PCGV-8-A-D-1-10 | 615078 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
F3-PCGV-8-A-D-1-10 | 506789 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
PCGV-8-A-1-10 | 615075 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI |
4CG1-10-DA-21UG | 462612 | RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL |
4CG1-10-DA-21UG | 462612 | RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL |
F3-4CG1-10-DA-21UG | 709132 | RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL |
4CT-06-DA-20UB | 464135 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI FUNCTION IS SAME, FORM AND FIT ARE SOMEWHAT DIFFERENT |
4CT-06-DA-20UB | 464135 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI FUNCTION IS SAME, FORM AND FIT ARE SOMEWHAT DIFFERENT |
4CG-06-DA-21 | 626520 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT |
4CG-06-DA-21 | 626520 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT |
4CG-10-DA-21 | 626543 | RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT |
DGMDC-5-Y-BL-30 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI THE RR W4 OPTION IS FOR SOFT SEAT FEATURE, VICKERS DOES NOT OFFER THIS, USE STANDARD |
DGMDC-5-Y-PL-30 | 02-395246 | RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI |
DGMDC-5-Y-PL-30 | 02-395246 | RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI |
DGMDC-5-X-TL-30 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI |
DGMDC-5-X-TN-30 | 868661 | |
DGMDC-3-X-BL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-X-BL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-X-AL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-X-AL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-YAL-BL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-YAL-BL-41 | REL PNDG | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-Y-PL-41 | 02-157021 | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-Y-PL-41 | 02-157021 | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-Y-PL-41 | 02-157021 | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-Y-PM-41 | 02-138605 | RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI |
DGMDC-3-Y-PM-41 | 02-138605 | RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI |
DGMDC-3-Y-PM-41 | 02-138605 | RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI |
DGMDC-3-X-TL-41 | 02-157275 | RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI |
DGMDC-3-X-TN-41 | 02-138524 | RR CRACKING PRESSURE IS 75 PSI, CLOSEST VICKERS IS 72 PSI |
DGMC2-5-ATGW-BTGW-B-30 | 868308 | |
DGMC2-5-ABFW-BAFW-30 | 868858 | |
DGMC2-5-ABGW-BAGW-30 | 867323 | |
DGMC2-3-ATBW-BTBW-41 | 871701 | |
DGMC2-3-ATCW-BTCW-41 | 870074 | |
DGMC2-3-ATGW-BTGW-41 | 871702 | |
DGMC2-3-ABCW-BACW-41 | 869628 | |
DGMFN-5-X-A2K-B2K-30 OR DGMFN-5-Y-A2K-B2K-30 |
867335 OR 867332 |
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER- OUT |
DGMFN-5-X-A2K-B2K-30 OR DGMFN-5-Y-A2K-B2K-30 |
867335 OR 867332 |
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER- OUT |
DGMFN-5-X-A2K-B2K-30 OR DGMFN-5-Y-A2K-B2K-30 |
867335 OR 867332 |
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER- OUT |
DGMFN-5-X-A2W-30 | 868880 | |
DGMFN-5-Y-A2W-30 | 868883 | |
DGMFN-7-Y-A2W-B2W-30 | 02-413078 | |
F3-DGMFN-7-Y-A2W-B2W-30 | 02-413080 | |
DGMFN-H8-Y-A2W-B2W-10 | 02-413088 | |
F3-DGMFN-H8-Y-A2W-B2W-10 | 02-413090 | |
DGMFN-3-X-B2W-41 | 870234 | |
DGMFN-3-X-A2W-B2W-41 OR DGMFN-3-Y-A2W-B2W-41 |
694414 OR 694412 |
RR CAN BE EITHER METER-IN OR -OUT BY HOW IT IS ASSEMBLED ON THE MANIFOLD. VICKERS HAS TO BE DESIGNATED IN THE ASSEMBLY X = METER-IN, Y = METER-OUT |
DGMFN-3-X-A2W-B2W-41 OR DGMFN-3-Y-A2W-B2W-41 |
694414 OR 694412 |
RR CAN BE EITHER METER-IN OR -OUT BY HOW IT IS ASSEMBLED ON THE MANIFOLD. VICKERS HAS TO BE DESIGNATED IN THE ASSEMBLY X = METER-IN, Y = METER-OUT |
DGMPC-5-ABK-BAK-30 | 867364 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-ABK-BAK-30 | 867364 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-ABK-BAK-30 | 867364 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-ABK-BAK-30 | 867364 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-ABK-30 | 867339 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-ABK-30 | 867339 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-BAK-30 | 867340 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-5-BAK-30 | 867340 | RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR |
DGMPC-7-ABK-BAK-30 | 02-413103 | |
F3-DGMPC-7-ABK-BAK-30 | 02-413105 | |
DGMPC-7-ABK-30 | 02-413102 | |
DGMPC-7-BAK-30 | 02-413106 | |
DGMPC-H8-ABK-10 | 02-413112 | |
DGMPC-H8-BAK-10 | 02-413114 | |
DGMPC-H8-ABK-BAK-10 | 02-413055 | |
F3-DGMPC-H8-ABK-BAK-10 | 02-413058 | |
DGMPC-3-ABK-BAK-41 | 694400 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-ABK-BAK-41 | 694400 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-ABK-BAK-41 | 694400 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-ABM-BAM-41 | 02-139087 | RR IS RATED TO 3 BAR, VICKERS IS 2,5 BAR |
DGMPC-3-ABK-41 | 870024 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-ABK-41 | 870024 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-ABK-41 | 870024 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-BAK-41 | 870023 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-BAK-41 | 870023 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMPC-3-BAK-41 | 870023 | RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR |
DGMC-5-AT-BW-B-30 | 868651 | |
DGMC-5-AT-FW-B-30 | 02-149394 | |
DGMC-5-AT-GW-B-30 | 868304 | |
DGMC-5-BT-BW-B-30 | 868652 | |
DGMC-5-BT-GW-B-30 | 868306 | |
DGMC-5-PT-GW-B-30 | 868300 | |
DGMC-3-AT-BW-41 | 02-138108 | |
DGMC-3-AT-CW-41 | 02-139196 | |
DGMC-3-AT-GW-41 | 02-108716 | |
DGMC-3-BT-GW-41 | 02-108133 | |
DGMX2-5-PA-FW-B-30, SEE COMMENTS | 02-101968 | RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT |
DGMX2-5-PA-FW-B-30, SEE COMMENTS | 02-101968 | RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT |
DGMX2-5-PA-GW-B-30, SEE COMMENTS | 868656 | RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT |
DGMX2-5-PA-GW-B-30, SEE COMMENTS | 868656 | RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT |
DGMX2-5-PB-FW-B-30 | 02-145043 | |
DGMX2-5-PB-GW-B-30 | 868657 | |
DGMX2-5-PP-FW-B-30 | 880553 | |
DGMX2-5-PP-FW-B-30 | 880553 | |
DGMX2-5-PP-FW-B-30 | 880553 | |
DGMX2-5-PB-GW-B-30 | 868655 | |
DGMX2-5-PB-GW-B-30 | 868655 | |
DGMX2-5-PA-FW-B-30, SEE COMMENTS | 02-101968 | THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-5-PA-GW-B-30, SEE COMMENTS | 868656 | THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-5-PB-BW-B-30, SEE COMMENTS | 868317 | THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-5-PP-FW-B-30, SEE COMMENTS | 880553 | THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS DIRECT OPERATED |
DGMX2-5-PP-GW-B-30, SEE COMMENTS | 868655 | THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS DIRECT OPERATED |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40 | 870033 | RR HAS THE CHECK IN THE A PORT, AND PILOTED FROM A, VICKERS HAS THE CHECK IN THE P PORT, BUT PILOTED FROM A, THE RESULT IS THE SAME, YOU HAVE REDUCED PRESSURE IN THE A LINE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-FW-B-40, SEE COMMENTS | 870033 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-CW-B-40, SEE COMMENTS | 870032 | RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER THIS FEATURE |
DGMX2-3-PA-CW-B-40 | 870267 | |
DGMX2-3-PP-FW-B-40 | 870038 | |
DGMX2-3-PP-FW-B-40 | 870038 | |
DGMX2-3-PP-FW-B-40 | 870038 | |
DGMX2-3-PP-FW-B-40 | 870038 | |
DGMX2-3-PP-RW-B-40 | 02-156823 | |