Vickers Equal (Model Code)Vickers Assembly #Remarks
FCG-H02-16-50BREL PNDG 
FCG-H02-50-50BREL PNDG 
F3-FCG-H02-50-50BREL PNDG 
FCG-H03-100-50BREL PNDG 
F3-FCG-H03-100-50BREL PNDG 
DG4V322AVMUH760871847 
DG17V32N60EN42202-148697 
DG17V32C6002-127343 
DG17V38C6002-140909 
DG17V36C6002-135316 
DG17V36C6002-135316DG17V-3 IS STANDARD VITON
DG17V36N6002-135673 
DG4V322AVMUH760871847 
DG4V30AVMUH760REL PNDG 
DG4V32AZVMUH760REL PNDG 
DG4V32AVMUH760859188 
DG4V32AVMUH760859188 
DG4V32AVMUH760P12REL PNDG 
DG4V32AVMUH760859188 
DG4V32AVMUB660870890 
DG4V32AVMUD660REL PNDG 
DG4V32NVMUH760859164 
DG4V32NVMUH760859164 
DG4V32NVMUH760P12REL PNDG 
DG4V32NVMUH760859164 
DG4V32NVMUDJ760859164 
DG4V32NVMUB66002-108674 
DG4V32NVMUD66002-145712 
DG4V32CVMUH760859213 
DG4V32CVMFTWLH760REL PNDG 
DG4V32CVMUB660870662 
DG4V32CVMUD660REL PNDG 
DG4V32C209VMUHH760REL PNDG 
DG4V30BLVMUH760REL PNDG 
DG4V30BMUH760  
DG4V36CVMUH760859183 
DG4V36CVMUH760859183 
DG4V36CVMUH760P12REL PNDG 
DG4V36CVMUH760859183 
DG4V36CVMUB660859486 
DG4V36CVMUD660870406 
DG4V36CVMUD660P10REL PNDG 
DG4V36BLVMUH760870875 
DG4V36BLVMUD660REL PNDG 
DG4V37CVMUH760870404 
DG4V32ALVMUH760859211 
DG4V32ALVMUH760P12REL PNDG 
DG4V32ALVMUH760859211 
DG4V32ALVMUB660859481 
DG4V32ALVMUD660870953 
DG3VP-3-103A-V-M-U-P-10507606 
DG3VP-3-103A-V-M-U-H-10638538 
DG3VP-3-103A-V-M-U-P-10507606 
DG3VP-3-102A-V-M-U-H-10638542 
DG3VP-3-102A-V-M-U-H-10638542 
DG4V522AJVMUH620REL PNDG 
DG4V522ALJVMUH620REL PNDG 
DG4V50AVMUEK620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W110 IS DUAL FREQUENCY
DG4V52AJVMUH620REL PNDG 
DG4V52NJVMUH620REL PNDG 
DG4V52NJVMUH620REL PNDG 
DG4V52NJVMUH620REL PNDG 
DG4V52AJVMUH620J12REL PNDG 
DG4V52CJVMUH620REL PNDG 
DG4V52CJVMUEK620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W110 IS DUAL FREQUENCY
DG4V52CJVMUEH620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W230 IS DUAL FREQUENCY
DG4V56CJVMUH620REL PNDG 
DG4V56CJVMUH620REL PNDG 
DG4V56CJVMUH620REL PNDG 
DG4V56CJVMUH620REL PNDG 
DG4V56CJVMUEK620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W110 IS DUAL FREQUENCY
DG4V56CJVMUEK620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W110 IS DUAL FREQUENCY
DG4V56CJVMUEH620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W230 IS DUAL FREQUENCY
DG4V531CJVMUH620REL PNDG 
DG4V52ALJVMUH620REL PNDG 
DG4V52ALJVMUEK620REL PNDGDG4V5 VALVES HAVE SINGLE FREQUENCY
COILS, RR W110 IS DUAL FREQUENCY
DG4V52ALJVMUH620J12REL PNDG 
DG5V56CTVMUH710REL PNDG 
DG17V4012N1002-356396 
DG17V4-01-6C-1002-356393 
DG17V4-01-6N-1002-356397 
DG4V5-6C-J-M-U-H6-20616780 
DG5V72AL4TVMUH730P10REL PNDG 
DG5V72AL4TVMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V72AL2TVMUH730REL PNDG 
DG5V72CTVMUH730REL PNDG 
DG5V72N4VMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
F3DG5V72N4VMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V72NTVMUH73002-146691 
DG5V72N4TVMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V72N2TVMUH730REL PNDG 
DG5V72N6TVMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V72N4EVMUH730P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V72N6TVMUB630P10, SEE COMMENTSREL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76CTVMUH73002-350591 
DG5V76CTVMUH73002-350591 
DG5V76C4TVMUH730P10REL PNDG 
DG5V76C4TVMUH730P10REL PNDG 
DG5V76C4TVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
F3DG5V76C4TVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
F3DG5V76CTVMUH73002-350591 
DG5V76C2TVMUH73002-358669 
DG5V76C6TVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76C6TVMUH730REL PNDG 
DG5V76C6TVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76C4EVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76C2PPDETVMUH730REL PNDG 
DG5V76C4HTVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76C4TVMUB630P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V76C4TVMUC630P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
F3DG5V72AL4TVMUH730P10REL PNDGRR D3 = PRESSURE REDUCING VALVE, VICKERS
DOES NOT OFFER THE OPTION WITH THE D07
ONLY ON D08, DG5V-8, VICKERS EQUAL IS WITHOUT THE REDUCER
IF A REDUCER IS NEEDED, AN MPS IS NEEDED TO CREATE A VERSION
DG5V-7 WITH IT
DG5V8HR2AEVMUHP1010REL PNDG 
DG5V8H2A2EVMUH10REL PNDG 
DG5V8HR2AEVMUBP1010REL PNDG 
DG5V8H2BLEVMUH10REL PNDG 
DG5V8HR2BLEVMUHP1010REL PNDG 
DG5V8HR2BLEVMUBP1010REL PNDG 
DG5V8SR2NTVMUHP1010REL PNDG 
DG5V8H6CVMUH10REL PNDG 
DG5V8SR6CTVMUHP1010REL PNDG 
DG5V8HR33C2EVMUHP1010REL PNDG 
DG5V72A4TVMUH730P10REL PNDGNO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING
MODULE
DG5V72A4TVMUH730P10REL PNDGNO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING
MODULE
DG5V72N6TVMUH730P10REL PNDGNO VICKERS OPTION FOR RR “D3” PRESSURE REDUCING
MODULE
DG5V8HR2ATVMUHP1010REL PNDGRR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT
USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS
DG5V8HR2AEVMUDP1010REL PNDGRR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT
USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS
DG5V8HR2A2EVMUDP1010REL PNDGRR MAINSTAGE USES SPRING RETURN, VICKERS DOES NOT
USE SPRINGS FOR THE *A (OFFSET) SPOOL MODELS
DG5V8HR2BLEVMUDP1010REL PNDG 
F3DG5V8HR2NTVMUHP1010REL PNDG 
DG5V8H6CTVMUH10REL PNDG 
DG5V8H6CTVMUH10REL PNDG 
DG5V8HR6CTVMUHP1010REL PNDG 
DG5V8HR6CTVMUHP1010REL PNDG 
F3DG5V8HR6CTVMUHP1010REL PNDG 
DG5V8H6C2TVMUH10REL PNDG 
DG5V8HR6C2TVMUHP1010REL PNDG 
DG5V8HR6CTVMUHP1010REL PNDG 
DG5V8HR6C2EVMUHP1010REL PNDG 
DG5V8HR6CTVMUBP1010REL PNDG 
DG5V8HR6CTVMUDP1010REL PNDG 
DG5V10S6CTVMUH1002-390437 
KDG4V333C07NZVMUH760REL PNDGMUST USE VICKERS ELECTRONICS
KDG4V333C07N03FVMUH760REL PNDGMUST USE VICKERS ELECTRONICS
KDG4V333C20N10ZVMUH760REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 30/15 L/MIN, VICKERS
IS 20/10 L/MIN
KDG4V333C20N10VMUH76002-411097MUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 30/15 L/MIN, VICKERS
IS 20/10 L/MIN
KDG4V333C20NZVMUH76002-156215MUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 30 L/MIN, VICKERS
IS 20 L/MIN
KBDG4V333C20N10ZVM2PE7H710REL PNDGRR SPOOL RATED TO 30/15 L/MIN, VICKERS
IS 20/10 L/MIN
KBDG4V333C13NZVM2PE7H710REL PNDGRR SPOOL RATED TO 15 L/MIN, VICKERS
IS 13 L/MIN, IF NECESSARY CAN GO WITH
33C20N SPOOL AND HAVE 20 L/MIN
KDG4V533C50N25ZVMUH730REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 60/30 L/MIN VICKERS
IS 50/25 L/MIN
KDG4V533C50N25VMUH73002-411098MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 60/30 L/MIN VICKERS
IS 50/25 L/MIN
KDG4V533C50NZVMUH730869901MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 60 L/MIN VICKERS IS 50 L/MIN
KFDG4V32C07NZVMU1H720565373MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 8 L/MIN, VICKERS
IS RATED 7 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V32C20NZVMU1H720565377MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16 L/MIN, VICKERS
IS RATED 20 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20N10ZVMU1H72002-358167MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16/8 L/MIN, VICKERS
IS RATED 20/10 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20N10ZVMU1H72002-358167MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16/8 L/MIN, VICKERS
IS RATED 20/10 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20N10ZVMU1H72002-358167MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16/8 L/MIN, VICKERS
IS RATED 20/10 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20N10ZVMU1H72002-358167MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16/8 L/MIN, VICKERS
IS RATED 20/10 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20NZVMU1H720565384MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 16 L/MIN, VICKERS
IS RATED 20 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V333C20NZVMU1H720565384MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 32 L/MIN, VICKERS
IS RATED 20 L/MIN
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V533C50N25ZVMUH720REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL 25/13 L/MIN SPOOL, VICKERS IS
50/25 L/MIN. CAN REF ASSY #02-352069,
KFDG4V533C50N25ZVMU1H720
KFDG4V533C50N25ZVMUH720REL PNDGMUST USE VICKERS ELECTRONICS
CAN REF ASSY #02-352069,
KFDG4V533C50N25ZVMU1H720
KFDG4V533C50N25ZVMUH720REL PNDGMUST USE VICKERS ELECTRONICS
CAN REF ASSY #02-352069,
KFDG4V533C50N25ZVMU1H720
KFDG4V533C50N25ZVMUH720REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS
50/25 L/MIN CAN REF ASSY #02-352069,
KFDG4V533C50N25ZVMU1H720
KFDG4V533C50N25ZVMU1H72002-352069MUST USE VICKERS ELECTRONICS
RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS
50/25 L/MIN ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KFDG4V533C50NZVMU1H720565321MUST USE VICKERS ELECTRONICS
ASSY GIVEN COMES WITH THE DIN
CONNECTORS ASSEMBLED ON THE VALVE
KBFDG4V35C20NZM1PE7H711 +
EHA-CON-201-A-20
REL PNDG +
5996156-001
RR SPOOL IS RATED 16 L/MIN, VICKERS
IS 20 L/MIN
THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, ±10mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V35C20NZVPE7H710 +
EHA-CON-201-A-20
REL PNDG +
02-104839
RR SPOOL IS RATED 16 L/MIN, VICKERS
IS 20 L/MIN
THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V333C07NZVPE7H710 +
EHA-CON-201-A-20
REL PNDG +
02-104839
RR SPOOL IS RATED 8 L/MIN, VICKERS
IS 7 L/MIN
THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V333C20N10ZVPE7H710 +
EHA-CON-201-A-20
REL PNDG +
02-104839
RR SPOOL IS RATED 8/4 L/MIN, VICKERS
IS 20/10 L/MIN, ONLY ASSYEMTRICAL SPOOL WE HAVE
IN THE KBFDG4V3. THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V59C50NZVPE7H710REL PNDG 
KBFDG4V533C50N25ZVPE7H710 +
EHA-CON-201-A-20
02-359630 +
02-104839
RR SPOOL IS RATED 75/38 L/MIN, VICKERS IS
50/25 L/MIN. THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V533C50NZVPE7H710 +
EHA-CON-201-A-20
02-352308 +
02-104839
THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG4V533C50NZVPE7H710 +
EHA-CON-201-A-20
02-352308 +
02-104839
THE EHA-CON-201-A-20 IS FOR THE
F1 CODE, 4-20mA INPUT COMMAND, KB IS 0-10VDC
KBFDG5V833C375N250XTM1PE7H410REL PNDGRR SPOOL IS 220/110 L/MIN, VICKERS IS 375/250 L/MIN
KBFDG5V833C375N250XTM2PE7H410REL PNDGRR SPOOL IS 220/110 L/MIN, VICKERS IS 375/250 L/MIN
KBFDG5V833C375N250XTM2PE7H410REL PNDGRR SPOOL IS 350/175 L/MIN, VICKERS IS 375/250 L/MIN
KBSDG4V596L80PE7H710 +
EHACON201A20
02-350062 +
02-104839
RR SPOOL IS RATED 100 L/MIN, VICKERS IS 80 L/MIN
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1
ON THE RR, VICKERS IS 0-10VDC
KBSDG4V396L40PE7H710 +
EHACON201A20
02-333476 +
02-104839
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1
ON THE RR, VICKERS IS 0-10VDC
INCOMPLETE CODE, MISSING THE
COMPLETE SPOOL CODE
  
KSDG4V396L40MU1H71102-310817MUST USE VICKERS ELECTRONICS
VALVE GIVEN COMES WITH DIN CONNECTOR PLUGS
ASSEMBLED ON THE VALVE
KBFDG4V59C50NZVPE7H710REL PNDG 
KBFDG4V35C20NZVPE7H710REL PNDGRR SPOOL RATED TO 4 L/MIN, VICKERS 20 L/MIN
LOWEST FLOW AVAILABLE IN ZERO LAP SPOOL
KBFDG4V35C20NZVPE7H710REL PNDGRR SPOOL RATED TO 10 L/MIN, VICKERS 20 L/MIN
LOWEST FLOW AVAILABLE IN ZERO LAP SPOOL
KBSDG4V396L05PE7H71002-333472RR SPOOL IS RATED 4 L/MIN, VICKERS IS 5 L/MIN
KBHDG5V52C100NXTPE7H410 +
EHACON201A20
02-359450 +
02-104839
RR SPOOL IS RATED 50 L/MIN, VICKERS IS 100 L/MIN
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1
ON THE RR, VICKERS IS 0-10VDC
KBHDG5V55C85NEXPE7H4105996495-001RR SPOOL RATED 100 L/MIN, VICKERS 85 L/MIN
KBHDG5V75C200NEXPE7H41002-350960RR SPOOL RATED 125 L/MIN, VICKERS 200 L/MIN
KBHDG5V75C200NXTPE7H410 +
EHACON201A20
REL PNDG +
02-104839
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1
ON THE RR, VICKERS IS 0-10VDC
KBHDG5V733C160NXTPE7H410 +
EHACON201A20
02-352351 +
02-104839
RR SPOOL IS RATED 125 L/MIN, VICKERS IS 160 L/MIN
THE EHACON201A20 IS FOR 4-20mA INPUT, CODE F1
ON THE RR, VICKERS IS 0-10VDC
KDG5V52C90NEXVMUH11002-359445MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 50 L/MIN, VICKERS 90 L/MIN
KDG5V52C90NXTVMUH11002-333827MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 85 L/MIN, VICKERS 90 L/MIN
KDG5V52C90NTVMUH11002-352717MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 85 L/MIN, VICKERS 90 L/MIN
KDG5V533C80NXTVMUH11002-323534MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 50 L/MIN, VICKERS 80 L/MIN
KDG5V533C80NXTVMUH11002-323534MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 50 L/MIN, VICKERS 80 L/MIN
KDG5V533C60N40XTVMUH11002-411790MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 50/25 L/MIN, VICKERS 60/40 L/MIN
KDG5V533C60N40XVMUH11002-358195MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN
KDG5V533C60N40XTVMUH11002-411790MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN
KDG5V533C60N40XTVMUH11002-411790MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 85/43 L/MIN, VICKERS 60/40 L/MIN
KDG5V72C180N100XTVMUH110REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150/75 L/MIN VICKERS 180/100 L/MIN
KDG5V733C170NXVMUH11002-318387MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150 L/MIN VICKERS 170 L/MIN
KDG5V733C170NXTVMUH11002-358953MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150 L/MIN VICKERS 170 L/MIN
KDG5V733C130N65XTVMUH11002-411791MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 100/50 L/MIN, VICKERS 130/65 L/MIN
KDG5V733C130N65XTVMUH11002-411791MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN
KDG5V733C130N65EVMUH110REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN
KDG5V733C130N65EXTVMUH110REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED 150/75 L/MIN, VICKERS 130/65 L/MIN
KDG5V833C270NXTVMUH11002-352401MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 220 L/MIN VICKERS 270 L/MIN
KDG5V833C270NXTVMUH11002-352401MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 220 L/MIN VICKERS 270 L/MIN
KDG5V833C270NXTVMUH11002-352401MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 325 L/MIN VICKERS 270 L/MIN
KDG5V833C250N170XTVMUH11002-411099MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN
KDG5V833C250N170XTVMUH11002-411099MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN
KDG5V833C250N170XVMUH11002-350373MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN
KDG5V833C250N170XTVMUH11002-411099MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN
KDG5V833C250N170XTVMUH11002-411099MUST USE VICKERS ELECTRONICS
RR SPOOL RATED 325/163 L/MIN VICKERS 250/170 L/MIN
KDG5V8133C250N170EXVMUH110REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED 220/110 L/MIN VICKERS 250/170 L/MIN
KDG5V102C550NXTVMUH111REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN
KDG5V1033C550NXTVMUH111REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN
KDG5V1033C550NXTVMUH111REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN
KDG5V1033C550NEXVMUH11102-396736MUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 360 L/MIN, VICKERS IS 550 L/MIN
KDG5V1033C550N310XTVMUH111REL PNDGMUST USE VICKERS ELECTRONICS
RR SPOOL RATED TO 520/260 L/MIN, VICKERS IS
550/310 L/MIN
KBDG5V52C70N45XTM1PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 85/43 L/MIN, VICKERS 70/45 L/MIN
KBDG5V533C80NXTM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 50 L/MIN, VICKERS IS 80 L/MIN
KBDG5V533C60N40XTM1PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN
KBDG5V533C60N40XTM2PE7H11002-353663EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN
KBDG5V533C60N40XTM2PE7H11002-353663EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 50/25 L/MIN, VICKERS IS 60/40 L/MIN
KBDG5V533C60N40XTM2PE7H11002-353663EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 85/43 L/MIN, VICKERS IS 60/40 L/MIN
KBDG5V72C180N100XTM1PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 150/75 L/MIN, VICKERS IS 180/100 L/MIN
KBDG5V733C130N65EM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 100/50 L/MIN, VICKERS IS 130/65 L/MIN
KBDG5V733C130N65XTM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 175/88 L/MIN, VICKERS IS 130/65 L/MIN
KBDG5V733C130N65EXTM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 175/88 L/MIN, VICKERS IS 130/65 L/MIN
KBDG5V82C330N200XTM1PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN
KBDG5V833C330NXTM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 325 L/MIN, VICKERS IS 330 L/MIN
KBDG5V833C330N200XTM2PE7H11002-411348EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 220/110 L/MIN, VICKERS IS 330/200 L/MIN
KBDG5V833C330N200XTM2PE7H11002-411348EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 220/110 L/MIN, VICKERS IS 330/200 L/MIN
KBDG5V833C330N200XTM2PE7H11002-411348EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN
KBDG5V833C330N200XTM2PE7H11002-411348EUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 325/163 L/MIN, VICKERS IS 330/200 L/MIN
KBDG5V102C550N310EXM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 520/260 L/MIN, VICKERS IS 550/310 L/MIN
KBDG5V1033C550N310XTM2PE7H110REL PNDGEUROPEAN SOLENOID IDENTIFICATION IS NOT
AN OPTION ON THIS SERIES
RR SPOOL RATED 360/180 L/MIN, VICKERS IS 550/310 L/MIN
SM4-20(5)19-300/30-50-S46,
+ SM4A-5-20-50
REL PNDG +
927783
RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm
S46 = REXROTH WIRING, NO NEED TO RE-WIRE CONNECTOR
SM4-20(12)45-300/30-50-S10,
+ SM4A-5-20-50
REL PNDG +
927783
S10 IS FOR 5TH PORT ACTIVATED, EXT PILOT
WHICH EQUALS RR “T”, WILL HAVE TO RE-WIRE
CONNECTOR, DO NOT HAVE A SPECIAL FOR S10+
S46 COMBINATION, MAY CONSIDER MPS TO CREATE ONE
RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm
SM4-10(2.5)9-300/30-10-S46
+ SM4A-3-10-10
REL PNDG +
686617
RR COIL IS 30mA/85ohm, VICKERS IS 30mA/300ohm
S46 = REXROTH WIRING, NO NEED TO RE-WIRE CONNECTOR
DARV-H-6-K-10/315REL PNDG 
DARV-W-10-G-10/100REL PNDG 
F3-DARV-W-10-G-10/100REL PNDG 
DARV-W-10-G-10/200REL PNDG 
DARV-W-10-G-10/315REL PNDG 
DARV-W-10-K-10/200REL PNDG 
DARV-W-10-K-10/25REL PNDG 
DARV-W-10-K-10/315REL PNDG 
DARV-W-10-P-10/200REL PNDG 
F3-DARV-W-10-P-10/200REL PNDG 
DARV-W-10-P-10/315REL PNDG 
NO VICKERSN/ARexroth Safety valve with design testing to DGRL 97/23/EG
NO VICKERSN/ARexroth Safety valve with design testing to DGRL 97/23/EG
DARV-W-20-G-10/200REL PNDG 
DARV-W-20-G-10/315REL PNDG 
DARV-W-20-K-10/315REL PNDG 
DARV-W-20-P-10/100REL PNDG 
DARV-W-20-P-10/200REL PNDG 
F3-DARV-W-20-P-10/200REL PNDG 
NO VICKERSN/ARexroth Safety valve with design testing to DGRL 97/23/EG
NO VICKERSN/ARexroth Safety valve with design testing to DGRL 97/23/EG
DARV-W-20-P-10/315REL PNDG 
F3-DARV-W-20-P-10/315REL PNDG 
DARV-W-20-P-10/400REL PNDG 
DARV-W-30-G-10/25REL PNDG 
DARV-W-30-K-10/200REL PNDG 
DARV-W-30-K-10/315REL PNDG 
DARV-W-30-P-10/200REL PNDG 
F3-DARV-W-30-P-10/200REL PNDG 
DARV-W-30-P-10/315REL PNDG 
DARV-W-6-G-10/200REL PNDG 
DARV-W-6-K-10/200REL PNDG 
DARV-W-6-K-10/315REL PNDG 
DARV-W-6-K-10/315-230REL PNDG 
DARV-W-6-P-10/100REL PNDG 
DARV-W-6-P-10/200REL PNDG 
DARV-W-6-P-10/315REL PNDG 
DARV-W-6-P-10/315-210REL PNDG 
F3-DARV-W-6-P-10/315REL PNDG 
DARV-W-6-P-10/400REL PNDG 
CG2V-6-FW-10615025 
CG2V-6-FW-1-10507130 
CG2V-6-GW-10615026 
CG2V-6-BW-10615023 
CG2V-8-CW-10615028 
CG2V-8-CW-10615028 
CG2V-8-FW-10615029 
CG2V-8-FW-10615029 
F3-CG2V-8-FW-10992376 
CG2V-8-FW-1-10992267 
CG2V-8-FW-10615029 
CG2V-8-GW-10615030 
CG2V-8-GW-10615030 
CG2V-8-GW-10615030 
CG2V-8-GW-10615030 
F3-CG2V-8-GW-10991901 
CG2V-10GW-B-1002-412582 
CG2V-10BW-B-U-1002-412579 
CG2V-10FW-B-1002-412580 
CG2V-10GW-B-10REL PNDG“E” not recognized in Rexroth model code
CG2V-10GW-B-1002-412582 
CG5V-6-GW-D-V-M-U-H7-11859544 
CG5V-6-GW-D-V-M-U-H7-11, W/O rexroth SPECIAL OPT NO INFORMATION ON SPECIAL OPT
CG5V-6-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT NO INFORMATION ON SPECIAL OPT
CG5V-6-GW-D-V-M-U-H7-11,W/O Rexroth SPECIAL OPT NO INFORMATION ON SPECIAL OPT
“A” NC TYPE NOT OFFERED IN VICKERS, ONLY THE “B” NO NO VICKERS
CG5V-8-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT NO INFORMATION ON SPECIAL OPT
CG5V-8-GW-D-V-M-U-H7-11, W/O Rexroth SPECIAL OPT NO INFORMATION ON SPECIAL OPT
CG5V-8-GW-D-V-M-U-HH5-20-P12-EN6REL PNDG
OR MPS
MAY TAKE AN MPS BECAUSE OF THE P12, 1,2MM ORIFICE
IN THE PILOT VALVE, EN6 IS FOR SOFTSHIFT PILOT TO EQUAL
RR “S” OPTION
CG5V-10GW-B-1-M-U-H7-1002-412650 
CG5V-10GW-B-2-M-U-H7-1002-412651“SO160” not recognized (preset at 160 bar?)
CG5V-10HW-B-2-M-U-H7-1002-412652“SO160” not recognized (preset at 160 bar?)
CG5V-10BW-B-U-2-M-U-H7-1002-412649 
KCG-6-W250-1-Z-M-U-H1-10 +
EEA-PAM-513-A-32
02-155961 +
02-326016
 
NO DIRECT VICKERS THE “M” IS FOR MAX PRESSURE PROTECTION, KCG SERIES
DOES NOT OFFER THAT, OLD CGE SERIES DID BUT IT IS AN
OUTDATED PRODUCT BEING PHASED OUT, AND IT DOES NOT
HAVE THE PRESSURE RATING OF THE RR
KCG-3-160-D-Z-M-U-H1-10
+ EEA-PAM-513-A-32
02-145957
+ 02-326016
 
KCG-3-250-D-Z-M-U-H1-10
+ EEA-PAM-513-A-32
02-145958
+ 02-326016
 
KCG-3-250-D-Z-M-U-H1-10
+ EEA-PAM-513-A-32
02-145958
+ 02-326016
 
KBCG-3-250-Z-M2-2-A-PE7-H1-1002-352751 
NO DIRECT VICKERS THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT
OPERATED VERSION
NO DIRECT VICKERS THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT
OPERATED VERSION
NO DIRECT VICKERS THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT
OPERATED VERSION
NO DIRECT VICKERS THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT
OPERATED VERSION
NO DIRECT VICKERS THESE ARE DIRECT ACTING, VICKERS ONLY HAS PILOT
OPERATED VERSION
XCG2V6CW10615003 
XCG2V6FW10615004 
XG2V6FW10709411 
XCG2V6GW10615005 
XG2V6GW10709412 
XCG2V6BW10615002 
XT-H10-3-3002-101800ONLY POSSIBLE VICKERS IN THIS MOUNTING TYPE,
VICKERS RATED 210 BAR, RR 315 BAR, RR IS 1″
VICKERS IS 1 1/4″
F3XCG22V8CW10991904 
XCG2V8FW10615008 
XG2V8FW10709416 
F3XCG2V8FW10507603 
XCG2V8GW10615009 
XCG2V8BW10615006 
XCG2V-10CW-B-1002-412641 
F3-XCG2V-10CW-B-1002-412642 
XCG2V-10FW-B-1002-412643 
XG2V-10FW-B-1002-412644 
F3-XCG2V-10FW-B-1002-412645 
XCG2V-10BW-B-1002-412647 
F3-XCG2V-10BW-B-1002-412648 
KBXCG-6-W250-Z-M1-3-A-PE7-H1-1002-352965 
KBXG-8-W250-Z-M1-3-A-PE7-H1-1002-353115 
CVU16-EFP1-B29-19-31 +
EEA-PAM-571-A-32
515866 +
02-326007
MUST USE VICKERS ELECTRONICS, EEA-PAM-571-A-32
CVU-32-EFP1-B29-70-31 +
EEA-PAM-571-A-32
02-156730 +
02-326007
RR RATED TO 450 L/MIN, VICKERS IS 700 L/MIN
MUST USE VICKERS ELECTRONICS, EEA-PAM-571-A-32
NO DIRECT VICKERS VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3
BOURDON PRESSURE TUBE STYLE
NO DIRECT VICKERS VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3
BOURDON PRESSURE TUBE STYLE
NO DIRECT VICKERS VICKERS S*307 PRESSURE SWITCHES ARE NOT LIKE THE HED3
BOURDON PRESSURE TUBE STYLE
ST307-350-B02-139179 
SG307-F-350 + DGMP-3-*-B-10 * = PORT CONNECTION TO PRESSURE SWITCH, THE REXROTH’S IS DETERMINED BY POSITION OF NEXT STACK PLATE. CHECK APPLICATION TO SEE WHICH PORT THEY ARE USING, THEN CHOOSE APPROPRIATE CODE. RR WOULD WORK FOR ANY
PORT BASED ON ASSEMBLY POSITION
CVI16R16L4002-156327RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR
VICKERS CLOSEST IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI25R16L4002-156356RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR
VICKERS CLOSEST IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFO ON THE -004
W/O IT CVI25R16M40
02-156364RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFO ON THE -004
W/O IT CVI25D202H10
580069RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI25D10H4002-156365RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 3,1 BAR
VICKERS RATE GIVES THE VICKERS THE BEST PERFORMANCE
WHEN USED WITH THE RELIEF COVER
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32R16L4002-156388RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32R16L4002-156388RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
F3CVI32R16L4002-359439RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32R16L4002-359439RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 1,0 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32D202L10815243RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST
IS 0,5 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFO ON THE -004
W/O IT CVI32R16M40
02-156396RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32D105M4002-156391RR HAS A RATIO OF 1:1.07 (14.3:1), VICKERS IS 1:1.05. ALSO
RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 1,65 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32D105H4002-156398RR HAS A RATIO OF 1:1.07 (14.3:1), VICKERS IS 1:1.05. ALSO
RR CRACKING PRESSURE IS 4,0 BAR, VICKERS IS 3,3 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI32D10H4002-156397RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 3,1 BAR
THIS IS FOR THE BEST PERFORMANCE WHEN USED WITH
VICKERS PRESSURE CONTROL COVERS
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40R16L4002-323089RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40R16L4002-323089RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 0,5 BAR
VICKERS IS 0,6 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40D202L10579932NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40R16M4002-323090RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40R16M4002-323090RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 2,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40R16M4002-323090RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 4,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFORMATION ON -004
W/O IT CVI40R16M40
02-323090RR HAS A 2:1 RATIO, VICKERS WITH THE DAMPENING FEATURE
ONLY HAS 1.6:1. ALSO RR CRACKING PRESSURE IS 4,0 BAR
VICKERS CLOSEST IS 3,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40D202H10579934RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST
IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
F3CVI40D202H10633048RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST
IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40C10FC4002-323120RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 2,35 BAR
FOR THE BEST PERFORMANCE WITH VICKERS PRESSURE
RELIEF COVERS
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFORMATION ON -104
W/O IT CVI40D10C40
02-323119RR CRACKING PRESSURE IS 2,0 BAR, VICKERS IS 2,35 BAR
FOR THE BEST PERFORMANCE WITH VICKERS PRESSURE
RELIEF COVERS
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI40X24002-323038ONLY VICKERS INSERT FOR PRESSURE REDUCING FUNCTION
NOT ENOUGH INFORMATON ON THE RR TO COMPLETELY
VALIDATE CROSS
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI50R2L10455998RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST
IS 0,5 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI50D202L10589114RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST
IS 0,5 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFORMATION ON -104
W/O IT CVI50D202M10
589115RR CRACKING PRESSURE IS 2,0 BAR, VICKERS CLOSEST
IS 2,5 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
DO NOT HAVE INFORMATION ON -104
W/O IT CVI50R2H10
455997RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST
IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI50D202H10589116RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST
IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI63R2L10456013RR CRACKING PRESSURE IS 1,0 BAR, VICKERS CLOSEST
IS 0,5 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
CVI63D202H10589139RR CRACKING PRESSURE IS 4,0 BAR, VICKERS CLOSEST
IS 5,0 BAR
NOTE:MUST USE VICKERS COVERS WITH VICKERS INSERTS, CANNOT
MIX AND MATCH WITH RR COMPONENTS
NO INFORMATION LCT SERIES  
NO INFORMATION LCT SERIES  
NO INFORMATIONON L-DB SERIES  
NO INFORMATIONON L-DB SERIES  
CVCS-16-W13-B29-10-A12-P12REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-16-D3-B29-10455820NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-16-D3-B29-10-AP108515316NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-25-N-B29-1002-156945NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-25-N-B29-10-X15REL PNDGVICKERS DOES NOT OFFER SEPARATE VERSION FOR THE RR
“F” OPTION, REMOTE CONTROL PORT, ON THE VICKERS THE
PILOT PORT CAN BE ACCESSED EXTERNALLY FOR REMOTE
CONTROL
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
NO INFORMATION ON THE 006
W/O IT CVCS-25-X3-B29-W350-11
02-318459NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-25-A-B29-W-1002-156453NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
NO INFORMATION  
CVCS-32-N-B29-1002-330771NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-N-B29-1002-330771NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-N-S2-10730414NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
NO VICKERS PRESSURE CONTROL COVER WITH 420 BAR PRESSURE ADJ
VICKERS MAX IS 350 BAR
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-W13-B29-1002-154714NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-W13-B29-10-A12-P12REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-A-B29-W-1002-344576NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-A-B29-W-1002-344576NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
F3-CVCS-32-A-B29-W-1002-344577NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-1002-154718NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-10-AP110-P10-T10REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-10-AP112REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-10-AP112-P15REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-10-P15REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-32-D3-B29-10-AP100-AP212REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-N-B29-1002-333629NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-N-B29-1002-333629NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-N-B29-10-X25REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-C-B29-W350-1102-342408NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-C-B29-W125-1102-319895NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-C-B29-W350-1102-342408NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-W13-B29-10-A12REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-W13-B29-10-A20REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-W13-B29-10REL PNDGVICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE
RR, USE STANDARD OR NO CROSS
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-A-B29-W-10-X12REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-A-B29-W-10-X12REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
NO VICKERS NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-D3-B29-10637287NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-D3-B29-10637287NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-D3-B29-10-AP115REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-40-D3-B29-10-AP115-P15REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
F3-CVCS-40-D3-B29-10-AP115REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-N-B29-1002-342721NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-N-B29-1002-342721NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-N-B29-1002-342721NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-N-B29-10-X18REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-N-B29-10-X30REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-W13-S2-10-S3202-330798THE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-W13-S2-10-S32-A15REL PNDGTHE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-W13-S2-10-S3202-330798THE S32 IS FOR USING THE S2 (INCH) STYLE THREADS BUT WITH METRIC MNTG HOLES FOR PILOT VALVE
VICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE
RR, USE STANDARD OR NO CROSS
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
NO INFORMATION  
NO VICKERS  
CVCS-50-D3-S2-10-S32-AP115REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-D3-S2-10-S32-AP115-P15REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-D3-S2-10-S32-AP130REL PNDGVICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE
RR, USE STANDARD OR NO CROSS
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-D3-S2-10-S32REL PNDGVICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE
RR, USE STANDARD OR NO CROSS
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVCS-50-D3-S2-10-S32REL PNDGVICKERS DOES NOT OFFER AN ORIFICE IN THE T PORT LIKE
RR, USE STANDARD OR NO CROSS
NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVC-63-N-B29-10456003NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVC-63-N-B29-10-X18REL PNDGNOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVC-63-N-B29-10-X3502-411792NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
CVC-63-A-B29-W-10456004NOTE: MUST USE VICKERS INSERTS WITH VICKERS COVERS
CANNOT MIX AND MATCH WITH RR COMPONENTS
DT8P1-06-15-11222319RR HAS 1/2 BSPP THREADS, VICKERS HAS 3/4 NPTF, DO NOT OFFER BSPP FOR THIS SERIES OR IN THE 1/2 SIZE
DT8P1-06-15-11222319RR HAS 3/4 BSPP THREADS, VICKERS HAS 3/4 NPTF, DO NOT OFFER BSPP FOR THIS SERIES
DT8P1-10-0-11-S261417856S261 VICKERS IS FOR NO SPRING WHICH IS EQUAL TO RR “0”,IT IS FOR LIGHT DUTY USE ONLY
DT8P1-10-5-11125667BOSCH HAS BSPP THREADS, VICKERS HAS NPTF, DO NOT OFFER
BSPP
DT8P1-03-5-10 BOSCH HAS BSPP THREADS, VICKERS HAS NPTF, DO NOT OFFER
BSPP
PCGV-6-A-D-1-10615045RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
F3-PCGV-6-A-D-1-10507359RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
PCGV-6-F-D-1-10615047 
PCGV-6-A-1-10615042RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
PCGV-8-A-D-1-10615078RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
F3-PCGV-8-A-D-1-10506789RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
PCGV-8-A-1-10615075RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 29 PSI
4CG1-10-DA-21UG462612RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI
TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN
THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS
SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL
4CG1-10-DA-21UG462612RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI
TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN
THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS
SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL
F3-4CG1-10-DA-21UG709132RR CRACKING PRESSURE IS 36 PSI, VICKERS IS 30 PSI
TYPICALLY THESE CROSS TO THE PCGV SERIES, BUT NO EQUAL IN
THE 30 SIZE, 4CG1-10 HAS SAME INTERFACE AND FUNCTION, FORM IS
SOMEWHAT DIFFERENT, 4CG1-10’S MAY OR MAY NOT STILL BE AVAIL
4CT-06-DA-20UB464135RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI
FUNCTION IS SAME, FORM AND FIT ARE SOMEWHAT DIFFERENT
4CT-06-DA-20UB464135RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI
FUNCTION IS SAME, FORM AND FIT ARE SOMEWHAT DIFFERENT
4CG-06-DA-21626520RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI
FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT
4CG-06-DA-21626520RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI
FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT
4CG-10-DA-21626543RR CRACKING PRESSURE IS 22 PSI, VICKERS IS 30 PSI
FUNCTION AND INTERFACE ARE THE SAME, FORM IS SOMEWHAT DIFFERENT
DGMDC-5-Y-BL-30REL PNDGRR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI
THE RR W4 OPTION IS FOR SOFT SEAT FEATURE, VICKERS DOES NOT
OFFER THIS, USE STANDARD
DGMDC-5-Y-PL-3002-395246RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI
DGMDC-5-Y-PL-3002-395246RR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI
DGMDC-5-X-TL-30REL PNDGRR CRACKING PRESSURE IS 7 PSI, VICKERS CLOSEST IS 5 PSI
DGMDC-5-X-TN-30868661 
DGMDC-3-X-BL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-X-BL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-X-AL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-X-AL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-YAL-BL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-YAL-BL-41REL PNDGRR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-Y-PL-4102-157021RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-Y-PL-4102-157021RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-Y-PL-4102-157021RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-Y-PM-4102-138605RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI
DGMDC-3-Y-PM-4102-138605RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI
DGMDC-3-Y-PM-4102-138605RR CRACKING PRESSURE IS 45 PSI, CLOSEST VICKERS IS 36 PSI
DGMDC-3-X-TL-4102-157275RR CRACKING PRESSURE IS 7 PSI, CLOSEST VICKERS IS 5 PSI
DGMDC-3-X-TN-4102-138524RR CRACKING PRESSURE IS 75 PSI, CLOSEST VICKERS IS 72 PSI
DGMC2-5-ATGW-BTGW-B-30868308 
DGMC2-5-ABFW-BAFW-30868858 
DGMC2-5-ABGW-BAGW-30867323 
DGMC2-3-ATBW-BTBW-41871701 
DGMC2-3-ATCW-BTCW-41870074 
DGMC2-3-ATGW-BTGW-41871702 
DGMC2-3-ABCW-BACW-41869628 
DGMFN-5-X-A2K-B2K-30 OR
DGMFN-5-Y-A2K-B2K-30
867335 OR
867332
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY
VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER-
OUT
DGMFN-5-X-A2K-B2K-30 OR
DGMFN-5-Y-A2K-B2K-30
867335 OR
867332
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY
VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER-
OUT
DGMFN-5-X-A2K-B2K-30 OR
DGMFN-5-Y-A2K-B2K-30
867335 OR
867332
RR CAN BE METER-IN OR METER-OUT BY POSITION AT ASSEMBLY
VICKERS NEEDS TO DEFINE IN THE CODE, X = METER-IN, Y = METER-
OUT
DGMFN-5-X-A2W-30868880 
DGMFN-5-Y-A2W-30868883 
DGMFN-7-Y-A2W-B2W-3002-413078 
F3-DGMFN-7-Y-A2W-B2W-3002-413080 
DGMFN-H8-Y-A2W-B2W-1002-413088 
F3-DGMFN-H8-Y-A2W-B2W-1002-413090 
DGMFN-3-X-B2W-41870234 
DGMFN-3-X-A2W-B2W-41 OR
DGMFN-3-Y-A2W-B2W-41
694414 OR
694412
RR CAN BE EITHER METER-IN OR -OUT BY HOW IT IS ASSEMBLED ON
THE MANIFOLD. VICKERS HAS TO BE DESIGNATED IN THE ASSEMBLY
X = METER-IN, Y = METER-OUT
DGMFN-3-X-A2W-B2W-41 OR
DGMFN-3-Y-A2W-B2W-41
694414 OR
694412
RR CAN BE EITHER METER-IN OR -OUT BY HOW IT IS ASSEMBLED ON
THE MANIFOLD. VICKERS HAS TO BE DESIGNATED IN THE ASSEMBLY
X = METER-IN, Y = METER-OUT
DGMPC-5-ABK-BAK-30867364RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-ABK-BAK-30867364RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-ABK-BAK-30867364RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-ABK-BAK-30867364RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-ABK-30867339RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-ABK-30867339RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-BAK-30867340RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-5-BAK-30867340RR CRACKING PRESSURE IS 1,5 BAR, VICKERS IS 1,0 BAR
DGMPC-7-ABK-BAK-3002-413103 
F3-DGMPC-7-ABK-BAK-3002-413105 
DGMPC-7-ABK-3002-413102 
DGMPC-7-BAK-3002-413106 
DGMPC-H8-ABK-1002-413112 
DGMPC-H8-BAK-1002-413114 
DGMPC-H8-ABK-BAK-1002-413055 
F3-DGMPC-H8-ABK-BAK-1002-413058 
DGMPC-3-ABK-BAK-41694400RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-ABK-BAK-41694400RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-ABK-BAK-41694400RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-ABM-BAM-4102-139087RR IS RATED TO 3 BAR, VICKERS IS 2,5 BAR
DGMPC-3-ABK-41870024RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-ABK-41870024RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-ABK-41870024RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-BAK-41870023RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-BAK-41870023RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMPC-3-BAK-41870023RR IS RATED TO 1,5 BAR, VICKERS IS 1 BAR
DGMC-5-AT-BW-B-30868651 
DGMC-5-AT-FW-B-3002-149394 
DGMC-5-AT-GW-B-30868304 
DGMC-5-BT-BW-B-30868652 
DGMC-5-BT-GW-B-30868306 
DGMC-5-PT-GW-B-30868300 
DGMC-3-AT-BW-4102-138108 
DGMC-3-AT-CW-4102-139196 
DGMC-3-AT-GW-4102-108716 
DGMC-3-BT-GW-4102-108133 
DGMX2-5-PA-FW-B-30, SEE COMMENTS02-101968RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS
FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS
THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT
DGMX2-5-PA-FW-B-30, SEE COMMENTS02-101968RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS
FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS
THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT
DGMX2-5-PA-GW-B-30, SEE COMMENTS868656RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS
FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS
THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT
DGMX2-5-PA-GW-B-30, SEE COMMENTS868656RR HAS REVERSE FLOW CHECK, VICKERS DOES NOT HAVE THIS
FEATURE, ALSO THE CHECK VALVE IS IN THE A PORT, VICKERS HAS
THE CHECK VALVE IN THE P PORT AND PILOTED FROM THE A PORT
DGMX2-5-PB-FW-B-3002-145043 
DGMX2-5-PB-GW-B-30868657 
DGMX2-5-PP-FW-B-30880553 
DGMX2-5-PP-FW-B-30880553 
DGMX2-5-PP-FW-B-30880553 
DGMX2-5-PB-GW-B-30868655 
DGMX2-5-PB-GW-B-30868655 
DGMX2-5-PA-FW-B-30, SEE COMMENTS02-101968THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS
DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK
VICKERS DOES NOT OFFER THIS FEATURE
DGMX2-5-PA-GW-B-30, SEE COMMENTS868656THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS
DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK
VICKERS DOES NOT OFFER THIS FEATURE
DGMX2-5-PB-BW-B-30, SEE COMMENTS868317THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS
DIRECT OPERATED, ALSO RR HAS FREE REVERSE FLOW CHECK
VICKERS DOES NOT OFFER THIS FEATURE
DGMX2-5-PP-FW-B-30, SEE COMMENTS880553THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS
DIRECT OPERATED
DGMX2-5-PP-GW-B-30, SEE COMMENTS868655THE RR “V” VERSION IS PILOT OPERATED, THE VICKERS ONLY OFFERS
DIRECT OPERATED
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40870033RR HAS THE CHECK IN THE A PORT, AND PILOTED FROM A, VICKERS
HAS THE CHECK IN THE P PORT, BUT PILOTED FROM A, THE RESULT
IS THE SAME, YOU HAVE REDUCED PRESSURE IN THE A LINE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-FW-B-40, SEE COMMENTS870033RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-CW-B-40, SEE COMMENTS870032RR HAS FREE REVERSE FLOW CHECK, VICKERS DOES NOT OFFER
THIS FEATURE
DGMX2-3-PA-CW-B-40870267 
DGMX2-3-PP-FW-B-40870038 
DGMX2-3-PP-FW-B-40870038 
DGMX2-3-PP-FW-B-40870038 
DGMX2-3-PP-FW-B-40870038 
DGMX2-3-PP-RW-B-4002-156823 
   
   
   
 
 